News Center
SF6 Decomposition device for pinggao

SF6 Decomposition device for pinggao

LH2-20Y/18WG/600 SF6 recovery unit-Henan pinggao Electric Co.,ltd-LH2-20Y/18WG/600 SF6 recovery unit: Functional characteristics :+Oil-free quick recovery ;+Negative pressure recovery up to 1,330Pa ;

[email protected]
News Detail
  • New SF6 Decomposition sorbent environmental

    New SF6 Decomposition sorbent environmental protection treatment device. Author:Winfoss Seeker Technology (Shanghai) Co., Ltd. Release time: 2018-05-17 Browsing [Winfoss China] 8 years of reputation, professional solutions to 30,000 customer product requirements and professional services [Online Inquiries] Hotline: 400-668-3536. [Introduction] Winfoss new environmental protection device

    Get Price
  • LH2-20Y/18WG/600 SF6 recovery unit_Henan pinggao

    LH2-20Y/18WG/600 SF6 recovery unit-Henan pinggao Electric Co.,ltd-LH2-20Y/18WG/600 SF6 recovery unit: Functional characteristics :+Oil-free quick recovery ;+Negative pressure recovery up to 1,330Pa ;

    Get Price
  • LH-20Y/18WG-I SF6 recovery unit_Henan pinggao

    LH-20Y/18WG-I SF6 recovery unit-Henan pinggao Electric Co.,ltd-+Oil-free recovery with recovery rate at 20m3/h ;+Oil-free recovery with recovery rate at 20m3/h ;+Negative pressure recovery, up to 13.3mbar, conforming to national standards;

    Get Price
  • SF6 Decomposition Gas Sensor Based on GeP

    The detection of sulfur hexafluoride (SF6) decomposition components is significant for monitoring the conditions of SF6-gas-insulated equipment. In present study, the adsorption of SF6 and its

    Get Price
  • Measuring device for<bRdecomposition products

    Measuring device for different decomposition products and gas residues For precise measurement. 3-032-R003 During the operation of gas insulated switchgear decomposition products might occur after a breakdown which has a negative impact on the gas quality in the circuit breaker as well as on the insulation properties.

    Get Price
  • On-line detection technology for SF6 decomposition

    The SF6 decomposition products online detection system has been mainly introduced from the aspects of principle, structure, detection effect, and practicability. and reliable device has

    Get Price
  • Optical technology for detecting the decomposition

    Zhang et al. 35 reported a UV-DOAS device for detecting SF 6 decomposition products with a portable design, and the schematic diagram is shown in Fig. 4. The device mainly comprised a light source, gas cell, spectrometer, and laptop. The differential absorption spectrum of SO 2 was obtained by performing Sym14Cited by: 5

    Get Price
  • 高压SF6开关设备气体分解物浓度在线监

    Translate this page该检测装置可用于实时监测SF6气体分解生成的SOF2气体体积分数,为研究SF6断路器内部放电和实现SF6气体分解物在线监测提供了可能。 Abstract: The concentration of gaseous decomposition products in SF6 circuit breakers serves as a criterion for the internal discharge modes and discharge energy.

    Get Price
  • Influence of moisture on SF6 decomposition

    In order to establish the theory and method for on-line electrical monitoring and fault diagnosis of electric equipment based on SF6 decomposition characteristics, we conducted SF6 decomposition

    Get Price
  • 王小华-等离子体生物医学研究中心

    Translate this page2020-6-3Y Fu, M Rong, K Yang, et al. C alculated rate constants of the chemical reactions involving the main byproducts SO2F, SOF2, SO2F2 of SF6 decomposition in power equipment, 2016, 49(15):155502. 5. L Zhong, A Yang, X Wang, et al. Dielectric breakdown properties of hot SF6-CO2 mixtures at temperature of 300-3500K and

    Get Price
  • An On-Line Monitoring System of SF6 Decomposition in

    This work is dedicated to the development of an on-line monitoring system of SF6 decomposition in electrical devices (SF6DcpMS) in order to evaluate the health condition of the devices in real time. The feature decomposition, SO2, and SF6 purity are continuously monitored. Considering the oxidation-reduction reactions of SO2Author: Hui Xuan Shi, Jin Qian, Xiao Bo Liu, Xiao Li Liu

    Get Price
  • Gas recovery device_Products_Henan pinggao Electric

    If you need to consult other business, you can call the hotline directly. General department: +86-375-3804029. Securities department: +86-375-3804064

    Get Price
  • DILO Arc By-products Measuring Device | Precise

    SF 6 Arc By-products Measuring Device For the precise measurement of SF 6 decomposition products . 3-032-R103. The DILO arc by-products measuring device for SF 6 features a smaller overall platform and robust housing, while retaining a rechargeable battery. With a response time of <15 seconds, self-sealing hoses and couplings, along with connections for discharge recovery systems, the SF 6

    Get Price
  • CA2504092A1 - Method and device for the detection of

    This invention is in the field of gas detection for sulphur hexafluoride (SF6) gas decomposition products, particularly for the detection of thionyl fluoride (SOF2) and sulphur dioxide (SO2). The invention relates to a novel portable handheld instrument that can readily detect SOF2, SF4 and SO2 in SF6 gas filled electrical equipmentCited by: 19

    Get Price
  • Multivariate Evaluation Method for Screening Optimum

    2020-7-24In previous studies, the selection of optimal gas-sensing materials for detecting target gases mainly relied on their response value, but other indices, such as the recovery capability of materials, have usually been overlooked. Here, we propose a new method for evaluating sensor effectiveness that includes a broaderAuthor: Jifeng Chu, Xu Yang, Aijun Yang, Dawei Wang, Huan Yuan, Xiaohua Wang, Mingzhe Rong

    Get Price
  • OSA | Highly sensitive photoacoustic multicomponent

    A ppb-level photoacoustic multicomponent gas sensor system for sulfur hexafluoride (SF6) decomposition detection was developed by the use of two near-infrared (NIR) diode lasers and an ultraviolet (UV) solid-state laser. A telecommunication fiber amplifier module was used to boost up the excitation optical power from the twoCited by: 8

    Get Price
  • SF6 positive DC partial discharge decomposition

    The condition monitoring and fault diagnosis method based on decomposed component analysis (DCA) for SF 6 gas‐insulated equipment, which mainly aiming at AC SF 6 gas‐insulated equipment, has become a research hotspot. Therefore, SF 6 positive DC partial discharge (PD) decomposition experiments under four typical

    Get Price
  • Technological innovation_Henan pinggao Electric Co.,ltd

    Technological innovation-Henan pinggao Electric Co.,ltd. Pinggao is the first company introducing SF6 circuit breaker manufacturing technology in 1979 from MG company in France, after several years of digestion, absorption and improvement, Pinggao made it to be homemade in 1986 and produce LW6 series (72.5 kV, 550

    Get Price
  • 浅谈SF6纯度及分解产物测试的改进_百度

    Translate this pagewenku.baidu.com›百度文库›互联网关键词: SF6;纯度及分解产物测试;改进 Key words: SF6;purity and decomposition product testing;improve 中图分类号:TM93 文献标识码:A 文章编号:1006-4311(2013)26-0043-02 0 引言 随着电网的不断发展,越来越多不同电压等级的电气设备采用

    Get Price
  • The research of temperature properties of photoacoustic

    Photoacoustic (PA) spectroscopy technology has proved to be effective in detection of SF6 decomposition products. But in the real application environment, the stability of the PA spectroscopy device is strongly affected by ambient temperature. In this paper, we took CO as an example to analyze the impact mec

    Get Price
  • Research on technology of online gas chromatograph for

    Hydrogen sulfide (H2S) is an important decomposition component of sulfur hexafluoride (SF6), which has been extensively used in gas-insulated switchgear (GIS) power equipment as insulating and arc

    Get Price
  • TiO2 Nanotube Array Sensor for Detecting the SF6

    The traditional SF6 decomposition gas sensor based on metal oxide semiconductor is still restrained by its disadvantages of high power consumption and poor selectivity, which limits its further

    Get Price
  • February SF6气体绝缘组合电器放电故障模式智能识别

    2020-2-17第46 卷 第2 期:432-440 高电压技术 Vol.46, No.2: 432-440 2020 年2 月29 日 High Voltage Engineering February 29, 2020 DOI: 10.13336/j.1003-6520.hve.20200131007 2020 年2 月29 日第46 卷February 高压SF 6气体绝缘组合电器放电故障模式智能识别

    Get Price
  • FAQ on SF6_图文_百度文库

    Translate this pagewenku.baidu.com›百度文库›互联网What substances can be created by See IEC 60480, Table 1 (Origin of SF6 impurities) and/or chemical reactions with these CIGRE Report Electra 1991 (Handling of SF6 and its decomposition products in the worst decomposition products in GIS, Table 2

    Get Price
  • iSF6-1602 PRO SF6 Decomposition

    Translate this pageThe decomposition analyzer iSF6-1602 PRO is configured with residue gas collecting and decomposition products analyzing. It is designed to measure precise SF6 moisture content, purity and decomposition products in GIS switchgear and high voltage equipment.

    Get Price
  • JPH06222104A - Gas insulation device failure gas

    (57) [Summary] [Purpose] To improve the reliability of failure detection in the gas classification of gas-insulated equipment. [Arrangement] Gas pressure sensors 21a and 21b and SF6 decomposition gas sensors 20a and 20b are provided in the same device, and arithmetic devices 23a and 23b for determining an abnormality whenAuthor: Hiroshi Maekawa, 洋 前川

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online