News Center
SF6 decomposition analysis for KEPCO

SF6 decomposition analysis for KEPCO

2018-10-22A simulation of Pd-doped SWCNTs used to detect SF6 decomposition components under partial discharge. Applied Surface Science, 2014, 315: 196-202. (SCI: 000342360300030) [4]Xiaoxing Zhang, Song Xiao, Junjie Zhou, Ju Tang. Experimental analysis

[email protected]
News Detail
  • SF6 decomposition multicomponent analysis system,SF6

    SF6 decomposition multicomponent analysis system,SF6 gas testing products,Products in the world,Beijing el technology co., LTD,Product model: SF6 - FTIR - 401Origin: Germany1. The SF6 features:Sulfur hexafluoride (SF6) gas, by two French chemist Mois

    Get Price
  • Analysis of PD-generated SF6 decomposition gases

    Hence, analysis techniques of SF6 decomposition can be applied to state monitoring of power apparatus. Finally, further issues needed solved and possible development directions were put forward.

    Get Price
  • sf 6 Decomposition laboratory - karina.net.pl

    sf 6 Decomposition laboratory. Sulfur hexafluoride (sf6 gas-gas) or sulphur hexafluoride (British spelling), is an extremely potent and persistent man-made and naturally occuring greenhouse gas that is primarily utilized as

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    2007-11-1Sulfur hexafluoride (SF 6) is being widely used in a variety of industrial processes, commercial products and scientific fields due to its unique characteristics such as relatively low toxicity, extreme inertness and high dielectrics.However, the chemically stable gas is one of the most potent greenhouse gases (GHGs) that

    Get Price
  • SF6 gas Mixtures Decomposition for subway

    SF6 gas Mixtures Decomposition for subway. PD can cause decomposition of sf 6 gas, resulting in the production of various low-fluorine sulfides, such as SF 4, SF 3, SF 2, and S 2 F 10. 1 – 3 Because of the presence of trace impurities, such as H 2 O and O 2, in the equipment, these low-fluorine sulfides generate many more stable decomposition

    Get Price
  • SF6 gas Mixtures Decomposition factorys

    SF6 gas Mixtures Decomposition factorys. D-Industrial Technology (Shanghai) Co., Ltd. Is dedicated to research and design SF6 gas leak detection and decomposition product analysis for industry, electric power industry, building venilation, elvevator buffer and other related equipment. D-Industrial is established in 2005 in

    Get Price
  • KEPCO Analysis cost

    In addition, KEPCO reduced next SCADA cost from 90.5million USD to 39.6 million USD on the basis of xGrids and enhanced its grid systems availability from 99.9% to 99.9999%. KEPCO has developed 16 intelligent applications on the xGrids during 2014-2019 coming up with a lot of business benefits. Get Price

    Get Price
  • 韩冬--中国科学院电工研究所 - CAS

    Translate this page“SF6 Gas Decomposition Analysis under Point-to-Plane 50-Hz AC Corona Discharge”, IEEE Trans. on Electrical Insulation, 22(2): 2015, 799-805. [2] Tao Lin, Dong Han*, Guoqiang Zhang, Yilu Liu, Qiang Yu.

    Get Price
  • KEPCO gas insulated substation for sale

    KEPCO gas insulated substation for sale. For proven solutions that meet specific substation power requirements, General Cable offers electric utility cables that include TransPowr ACSR, AAC and 1350-0 bare overhead transmission conductors, bare copper and Dead Soft Annealed Copper Clad Steel (DSA CCS) grounding

    Get Price
  • 方勇华(中国科学院安徽光机所研究

    Translate this pagebaike.baidu.com›方勇华的概述图人物经历

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment - IEEE

    Abstract: The increasing application of SF6 as an insulating gas has led to many studies on SF6 decomposition in gas-insulated equipment. In the presence-of an electric arc, spark or corona, SF6 decomposes to a wide variety of chemically active products which possess completely different properties from SF6.

    Get Price
  • Highly Sensitive and Precise Analysis of SF6

    A ppb-level CO sensor based on multi-comb optical-feedback cavity enhanced absorption spectroscopy with a 2.3 μm diode laser was developed for SF6 decomposition analysis in electric power system.

    Get Price
  • 武汉大学电气与自动化学院

    Translate this page2018-10-22A simulation of Pd-doped SWCNTs used to detect SF6 decomposition components under partial discharge. Applied Surface Science, 2014, 315: 196-202. (SCI: 000342360300030) [4]Xiaoxing Zhang, Song Xiao, Junjie Zhou, Ju Tang. Experimental analysis

    Get Price
  • Multivariate Evaluation Method for Screening Optimum

    2020-7-24In previous studies, the selection of optimal gas-sensing materials for detecting target gases mainly relied on their response value, but other indices, such as the recovery capability of materials, have usually been overlooked. Here, we propose a new method for evaluating sensor effectiveness that includes a broaderAuthor: Jifeng Chu, Xu Yang, Aijun Yang, Dawei Wang, Huan Yuan, Xiaohua Wang, Mingzhe Rong

    Get Price
  • 低微水的体积分数对SF6局部放电及分解

    Translate this page[1]汲胜昌, 钟理鹏, 刘凯, 等. SF6放电分解气体组分分析的现状和发展 [J]. 中国电机工程学报, 2015, 35(9): 23182332. JI Shengchang, ZHONG Lipeng, LIU Kai, et al. Research status and development of SF6 decomposition components analysis under

    Get Price
  • SF6 positive DC partial discharge decomposition

    The condition monitoring and fault diagnosis method based on decomposed component analysis (DCA) for SF 6 gas‐insulated equipment, which mainly aiming at AC SF 6 gas‐insulated equipment, has become a research hotspot. Therefore, SF 6 positive DC partial discharge (PD) decomposition experiments under four typical

    Get Price
  • The SF6 Decomposition Mechanism: Background and

    2017-1-24Gas Insulated Switchgear (GIS) has been widely used in substations. The insulating medium used in GIS is sulfur hexafluoride (SF6) gas. However, the internal insulation defect existed in GIS would inevitably lead to partial discharge (PD), and cause the composition of SF6 to SOF2, SO2F2 and SO2 and other characteristic component gases. The decompositionCited by: 1

    Get Price
  • Sensitivity Characteristic Analysis of Adsorbent

    Sensitivity Characteristic Analysis of Adsorbent-Mixed Carbon Nanotube Sensors for the Detection of SF6 Decomposition Products under PD Conditions November 2013 Sensors 13(11):15209-15220

    Get Price
  • KEPCO Develops SF6 Recycling Device to Combat

    The KEPCO Research Institute has been developing SF6 refining and decomposition technology since 2016. In June, the research center completed the development of SF6 refining equipment. SF6 becomes a solid matter at a temperature of minus 100 degrees Celsius. An SF6 refining device keeps SF6 and emits other gases at this

    Get Price
  • Analysis of SF 6 Solid Decomposition Products after

    Analysis of SF 6 Solid Decomposition Products after Breaking Tests. April 2019; DOI: 10.1109/ICEMPE.2019.8727307. Conference: 2019 2nd International Conference on Electrical Materials and Power

    Get Price
  • CN103105441B - Qualitative and quantitative analysis

    The invention discloses a qualitative and quantitative analysis method for a sulfur hexafluoride (SF6) gas discharge decomposition product. The method comprises the following steps of: sampling; performing qualitative and quantitative analysis on a sample by a gas chromatograph-mass spectrograph, wherein a quadrupole rodAuthor: 裘吟君, 陈晓琳, 陈林聪, 张薇, 李欣然

    Get Price
  • A Pt-Doped TiO2 Nanotube Arrays Sensor for Detecting

    The detection of partial discharge and analysis of SF6 gas components in gas-insulated switchgear (GIS) is important for the diagnosis and operating state assessment of power equipment. The use of a Pt-doped TiO2 nanotube arrays sensor for detecting sulfur hexafluoride (SF6) decomposition products is proposed in this

    Get Price
  • SF6 Decomposition Content Analyzer Manufacturers

    2021-1-14LK406 SF 6 Decomposition SO 2,HF,H 2 S Content/ Purity /Moisture On line system is based on the current power system to further improve production safety requirements, provide decomposition products of SF 6 analysis of real-time monitoring of the design, development of intelligent online detection system for SF 6 equipment. The systems main to detect water content, SF 6

    Get Price
  • Sensors | Free Full-Text | Analysis of the Sensitivity of

    Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decompositionCited by: 1

    Get Price
  • Sc doped arsenene as adsorbent for the

    Translate this page2021-3-15Sc doped arsenene as adsorbent for the detection and removal of SF6 decomposition gases: a DFT Applied Surface Science ( IF 6.182) Pub Date : 2021-03-14, DOI: 10.1016/j.apsusc.2021 Xiaohua Wang, Guohong Fan, Xianxian Tu, Xin Liu, Chenyin Li, Hong Xu

    Get Price
  • Sensitivity Characteristic Analysis of Adsorbent-Mixed

    2014-6-21decomposition product gas, and R 0 is the initial resistance value of the sensor under vacuum. (3) When the test was finished, SF 6 decomposition product gas was pumped from the cylinder and N 2 gas was passed into the cylinder to ensure that there was no residual gas present. The above steps were repeated to

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    Request PDF | Fourier transform infrared spectroscopy quantitative analysis of SF6 partial discharge decomposition components | Gas-insulated switchgear (GIS) internal SF6 gas produces specific

    Get Price
  • 吴永谦

    Translate this page2019-12-17Wu Y Q , Song S J, Chen D C, et al. Mono and bi molecular adsorption of SF6 decomposition products on Pt doped graphene: A First principles investigation[J]. Applied Sciences, 2018,8(10). Zhang X X, Zhang G Z, Wu Y Q et al Synergistic treatment of SF6 by dielectric barrier discharge/Al2O3 catalysis [J].

    Get Price
  • 汪沨-湖南大学电气与信息工程学院 -

    Translate this page2020-11-21一、基本情况汪沨,男,1972年5月生,教授、博士生导师,2014.11-2020.6任湖南大学电气与信息工程学院副院长,现任湖南大学高电压与绝缘技术方向学科带头人,高电压研究所所长,教育部新世纪优秀人才、天山学者。主要学术兼职包括,中国机械工业教育协会高电压与绝缘技术分委会委员;中国

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online