    information.” Coordinating with the AFRICA GIS Conference, the WSSD focuses on the importance of building data partnerships and technology standards for sharing geographic information among many agencies across the continent. Its hope is to make GIS accessible at all levels of enterprise so information is readily

    Get Price
  • GIS Substation Design and Execution HV and EHV GIS

    zA GIS is the implementation, within a complete HV substation, of the remarkable sulphur hexafluoride (Sulfr hexafluoride) properties in terms of voltage withstand and current interruption zsf6 gas main data zNeutral gas: insulators and live parts are perfectly protected from contamination and oxidation zDensity 6.15 kg/m3 at atmospheric pressure

    Get Price
  • Gas-insulated switchgear from 72.5 to 550 kV

    reliability. Ever since, Siemens GIS have played a central role in supplying power safely, worldwide. Today, Siemens has installed more than 28,000 indoor and outdoor switch bays worldwide, and well over 300,000 bay-years of operation have been recorded. Siemens supplies GIS for rated voltages from 72.5 kV up to 550 kV. The compre-

    Get Price
  • Gas insulated power transformers: A growing technology - EE

    Gas insulated switchgear is commonly used in substations and the development of gas insulated transformers allows complete integration of substation equipment with resultant space and cost savings. Gas insulated transformers (GITs) have been in use since the 1960s, but use has been restricted due to higher costs and other reasons.

    Get Price
  • The basics of Gas Insulated Substation (GIS) for students | EEP

    Nov 22, 2018 · GIS has a reduced “footprint” than a corresponding air insulated substation, usually less than half the area. Even though a gas isolated substation will initially cost more than a similar air insulated substation, the economics may rationalize its installation where land is pricey, such as city centres.

    Get Price
  • Gas Insulated Substation (GIS) Advantages - Disadvantages

    Jan 02, 2014 · The Sulfr hexafluoride Gas Insulated Substation (GIS) contains the same compartments as in the conventional outdoor substations. All the live parts are enclosed in metal housings filled with insulating gas gas . The live parts are supported on cast resin insulators.

    Get Price
  • PSEG Contracts for High-Voltage Gas-Insulated Substation to

    Siemens has been awarded a contract by New Jersey-based Public Service Electric and Gas Co. (PSEG), one of the largest electric utilities in the U.S., for the design, engineering, manufacturing, installation, testing and commissioning of an indoor 230-kV, 4000-A, 80-kA gas-insulated substation (GIS) and associated gas-insulated bus (GIB). The GIS is an expansion of the existing Bergen switching station located in Ridgefield, New Jersey.

    Get Price
  • Power Line and Substation Design - Trans-Africa Projects

    Power Line and Substation Design. Trans-Africa Projects (TAP) specialises in the design of overhead power lines and the supporting structures for these lines. We have been involved in various projects from 11 kV through to 765 kV voltage levels for both new-build and refurbishment/normalisation projects. Trans-Africa Projects is frequently engaged in different engineering aspects of projects, and the full range of services offered is outlined below.

    Get Price
  • Substation and switchgear techs: GIS is seen - ESI Africa

    May 22, 2018 · The battle between insulated substation technologies is not new, says Ahmed Mousa, Manager: Distribution 69kV Transmission Planning at PSEG, US but the differences between Air Insulated Switchgear and Gas Insulated Switchgear as well as the elements that make gas more attractive than air, remains a topic of interest.

    Get Price
  • High-voltage product services | Product support for power

    High-voltage equipment and other energy infrastructure typically last well beyond its warranty period. More than 2,000 Siemens employees around the world are ready to support your equipment throughout its entire useful life, ensuring best performance, highest availability and efficiency for your machines and systems as well as a secure and stable power supply for decades.

    Get Price
  • CONSTRUCTION DESIGN FEATURES OF GAS INSULATED SYSTEM (GIS)

    Very fast transient over voltage (VFTO) is a unique electromagnetic transient phenomenon occurring in Gas Insulated Substation (GIS), which determines the insulation level of the GIS (above 330 kV).

    Get Price
  • GIS substations - Hitachi ABB Power Grids

    Hitachi ABB Power Grids substations with gas-insulated switchgear (GIS) are unmatched when it comes to compactness, reliability, efficiency and safety, ensuring maximum power availability for utility, commercial and industrial customers. The robust and low maintenance GIS based design minimizes the substation’s footprint by as much as 70 percent, enabling it to be installed indoors, in busy urban areas and in harsh environments.

    Get Price
  • Gas Monitor System, Compartments and Zones for GIS - An

    May 25, 2019 · Gas Monitor System: The insulating and interrupting capability of the sf6 gas gas depends on the density of the Sulfr hexafluoride gas is at a minimum level established by design tests. The pressure of the gaz sf6 gas varies with temperature, so a mechanical temperature-compensated pressure switch is used to monitor the equivalent of gas density. GIS is…

    Get Price
  • GIS vs AIS - Substation Earthing

    Jan 31, 2019 · AEG GIS gas insulated switchgear up to 420 kV. Compressed sf6 gas gas used in MV and HV switchgears as an insulating medium has led to the development of compact gas-insulated substation (CIS) technology (figure 1). GIS, having many advantages over often used and conventional air-insulated substations (AIS), have been receiving wide application.

    Get Price
  • Gis substation - SlideShare

    Jul 12, 2014 · Comparison of GIS and AIS substation 11. Drawbacks of GIS 12. Growth of GIS substation 13. Future trends in GIS 14. Conclusion Contents 3. Introduction and governing standard This presentation covers the technical requirements and design aspects of a gas-insulated substation (GIS) as per governing standards of GIS substations.

    Get Price
  • Jornada técnica en subestaciones

    4 IEEE GIS-GIL References Standards C37.123 7 C37.122 Standard for High Voltage Gas-Insulated Substations, rated above 52 kV C37.122.1 GIS User Guide

    Get Price
  • Construction of 33/11Kv GIS Substations (2 x 31.5 MVA

    The contract shall include all works and materials needed in each substation in accordance with the contract and shall include but not limited to the following: (a) Option 1: 33kv switchgear contain: 1- two of 33kv incomer panel. 2- two of 33kv outgoing transformer panel. 3- one bus – section panel.. 4- one of bus riser panel.

    Get Price
  • GIS in Africa - ESRI

    GIS BEST PRACTICES 3 WWW.ESRI.COM Global Dialogues: GIScience and Sustainable Development in Africa "Crossing Borders" A column by Doug Richardson, Executive Director, Association of American Geographers

    Get Price
  • Tim Hornby - Director - GTR Transmission Protection

    Mar 05, 2016 · TP141 – Advanced Commissioning Authorisation National Grid United Kingdom 400kv/132kv GIS AIS projects for National Grid UK within high profile London based substations. Supergrid transformers commissioning ATCC Operations 275kv Mesh Corner works 13kv Reactors / HAM / LVAC / REB Busbar Protection / 400kv CB GIS

    Get Price
  • Tracking the pros cons of air and gas substations - ESI Africa

    Jun 28, 2018 · Tracking the pros cons of air and gas substations. Taking into consideration that the cost of a GIS indoor substation is much higher compared to an AIS substation, it’s handy to have a quick reference guide to the pros and cons of both indoor and outdoor substations, writes John Greyling, switchgear specialist and Director of Hevilex, South Africa.

    Get Price
  • AC High Voltage Circuit Breakers - Institute of Electrical

    (GIS). •Hybrid switchgear allows to reduce the size of substations and to combine the advantages of AIS and GIS. •Specific IEC standard: IEC 62271-205. •Circuit breaker is of GIS or Dead tank type •Depending on the capacitance of the liaison to overhead lines, it is considered as a GIS or AIS circuit breaker.

    Get Price
  • Home - HMV Engineering

    This has given us the confidence to engage them for a number of high voltage substations to service our facilities.“ Mission Critical Client “HMV engineering has delivered a number of contestable build 110 kV stations for major connections to the transmission system.

    Get Price
  • End of life estimation of HV switchgear and GIS substations

    GIS is characterised by high service reliability, low maintenance expenditure and long lifetimes. GIS technology requires more investment costs compared to air-insulated substations (AIS), however, due to its space saving features, this technology often offers the only solution where available space is limited.

    Get Price
  • Bay Control for GIS Transmission Substations

    Bay Control for GIS Transmission Substations The control solution ensures safe and reliable control of GIS substations on transmission levels. It includes all components needed for the local supervision and control of a complete feeder and provides remote access interfaces.

    Get Price
  • SUBSTATION DESIGN AND EQUIPMENT SELECTION SAIEE-1865-V, 3 CPD

    A. Substation Electrical Configurations and Reliability 1. Substation Design Criteria 2. Different substation types: Transformation vs. Switching, Transmission vs. Distribution vs. Collector substation 3. Substation definitions according to Cigré: Components, Bays, Switchgear, Substation 4. Substation Components and Arrangements 5.

    Get Price
  • 6. BIOMASS ESTIMATES FROM GIS MODELING

    Estimates of potential and actual biomass (density and total), as determined by modelling in a GIS, for most of the tropical countries in tropical Asia and Africa are shown in Table 6.1. Many of these values can be compared to the biomass density estimates given in Section 5 as a means of validating the modelling results.

    Get Price
  • (PDF) Points to consider regarding the insulation

    The survey suggests that 61% of the failures occurred at nominal voltage and 39 % occurred for AC overvoltage and / or switching. Only one failure due to lightning had been reported.

    Get Price
  • Maps | Data Basin

    Data Basin is a science-based mapping and analysis platform that supports learning, research, and sustainable environmental stewardship.

    Get Price
  • Electric Substations - ArcGIS

    This feature class/shapefile is for the Homeland Infrastructure Foundation Level Database (HIFLD) ( gii.dhs.gov/HIFLD) as well as the Energy modelling and simulation community.

    Get Price
edge-iconRelated News
toTop
Click avatar to contact us
Chat Online